• Outdoor High-Voltage Porcelain Drop Fuse
  • Outdoor High-Voltage Porcelain Drop Fuse
  • Outdoor High-Voltage Porcelain Drop Fuse
  • Outdoor High-Voltage Porcelain Drop Fuse

Outdoor High-Voltage Porcelain Drop Fuse

Type: High-voltage
Structure: Single-column Disconnector
Installation: Outdoor High-voltage
Operation: Manual
Grounding Mode: Grounding
Movement Mode: Plug-in Type
Samples:
US$ 15/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Zhejiang, China
to see all verified strength labels (20)

Basic Info.

Model NO.
RW12-12F/100(200)A
Number of Poles
Unipolar
Grounding
Single Ground
Series
Single-Stage
Run
Swing
Switching Mode
Single Throw-in
Structure of Operating
Manual
Certification
ISO9001
Brand
Zhengyuan
Transport Package
Wooden Box
Specification
41× 31× 12.5cm
Trademark
Zhengyuan
Origin
Zhejiang China
Production Capacity
9000 Branches/Year

Product Description

General
Drop-out fuse and pull loads falling type fuse protection for outdoor high-voltage electricalappliances, installed in the high-voltage side of distribution transformeror distribution lines branch trunk road, used as a transformer and line short-circuit, overload, and points. All load current. Drop
-outfuse holder and fuse from the insulating tube 2 parts. Static contact bracket installed in the insulation at both ends, moving contact is installedon both ends of fuse tube, fuse tube from the inner arc tube and the outer phenolic Aldehyde paper tube or epoxy glass cloth into the pipeline. Pull load drop fuse increase of auxiliary contact and interrupter cover for the points, combined load current.
Drop-fuse during normal operation, the fuse tube fuse with the formation of closed position after tensioning. When a system failure, the fault current to fuse rapidly fuse and form arc, arc tube by the electric arc burning, Decomposition of large quantities of gas, so that the formation of a high pressuretube, and the formation of vertical wind along the pipeline, and the arc was quickly stretched out. Fuse Fuse, the lower part of moving contacts lost tension turned down, locking machines, the release of fuse Tube, drop tube fuse to form a clear breaking position. When you need to pullload, dynamic contact with the insulating rod pull, this time the initiative to help contact remained static contact, continue to use the insulating rod then moving contacts, auxiliary contact can be divided into Away in the auxiliary contact arc between the arc in the eradication of cover slit was elongated at the same time interrupter cover produce gas, in the zero-current will arc out.
Technical parameter
Type
Rated 
Voltage
(KV)
Rated 
Current
(A)
Breaking
Current
(A)
Impulse
Voltage
(BIL)
Power-
frequency
withstand
Voltage
(KV)
Leakage
distance
(mm)
Weight
(kg)
Dimensions
(cm)
RW10-15F 15 100 6300 110 42 230 7.5 41×31×12.5
RW10-15F 15 200 12500 110 42 230 8 41×31×12.5
Outdoor High-Voltage Porcelain Drop FuseOutdoor High-Voltage Porcelain Drop FuseOutdoor High-Voltage Porcelain Drop FuseOutdoor High-Voltage Porcelain Drop Fuse
Outdoor High-Voltage Porcelain Drop FuseOutdoor High-Voltage Porcelain Drop Fuse
Outdoor High-Voltage Porcelain Drop Fuse

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
21
Year of Establishment
2017-06-08